Files to download

ECOCONDENS SILVER PLUS

A
A
A
Gas condensing boilers line ECOCONDENS SILVER PLUS – one of the most modern and smallest devices in the European market. Thanks to transparent control panel these boilers are very easy to use. Advanced design and compact sizes make them fit in every kitchen and other rooms as well. Wide range of modulation allows the boilers to heat very small areas and objects with low heat demand. Devices are adapted to work with solar systems, heat pumps and multi-zone hydraulic separators.
  • energy class: A
  • heat exchanger with one coil made of stainless steel
  • wide modulation range: from 12 to 100%
  • electronically controlled modulating fan
  • cylinder burner made of stainless steel – low level of NOx emission (6th class)
  • hydraulic group (hydroblock) assembled on quick-connector
  • complete protection system
  • additional noise insulation provides quiet operation of the boiler (only 48 dB)
  • optimization of boiler operation is possible due to application of:
    • outdoor temperature sensor
    • temperature regulator: ON/OFF, Open-Therm or 0-10V,
    • ROUND system for remote boiler control via smartphone,
    • EVOHOME system for remote control of up to 11 heating zones
    • ready-to-use multi-zone modules for controlling up to 3 SIM heating systems
  • boilers can also cooperate with:
    • heat pumps air/water
    • solar panels
    • domestic hot water cylinder by 3-way valve (concerns system boilers)
  • possibility of remote monitoring of the boiler by service technician (LIN system)
Parameters Value
Thermal power (at temp. 80/60°C) 2,7 - 20,0 kW
Thermal power (at temp. 50/30°C) 3,0 - 22,0 kW
Heat load 2,8 - 20,4 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
97,6 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
107,9 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
20,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
6,6 kW
Efficiency η4 88,3 %
Efficiency η1 98,8 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40-80 °C
Reduced adjustable temperature 25-55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 2,7 - 25,0 kW
Nominal heat load 2,8 - 25,6 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 97,6 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 12,0 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 21 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,07 kW
Electricity consumption at partial load elmax 0,06 kW
Type and supply voltage ~230±10%/50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 785 x 400 x 334 mm
Weight 33,5 kg
Domestic water connection G1/2 inch
Exchanger material stainless steel
Parameters Value
Thermal power (at temp. 80/60°C) 3,9 - 24,0 kW
Thermal power (at temp. 50/30°C) 4,3 - 26,5 kW
Heat load 4,0 - 24,6 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,7 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
24,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
7,9 kW
Efficiency η4 89,0 %
Efficiency η1 98,4 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40-80 °C
Reduced adjustable temperature 25-55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,9 - 30,0 kW
Nominal heat load 4,0 - 30,7 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 14 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 24 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,07 kW
Electricity consumption at partial load elmax 0,06 kW
Type and supply voltage ~230±10%/50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 785 x 400 x 334 mm
Weight 33,5 kg
Domestic water connection G1/2 inch
Exchanger material stainless steel
Parameters Value
Thermal power (at temp. 80/60°C) 4,1 - 34,7 kW
Thermal power (at temp. 50/30°C) 4,5 - 38,2 kW
Heat load 4,2 - 35,6 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
109,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
34,7 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
11,5 kW
Efficiency η4 88,4 %
Efficiency η1 98,3 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40-80 °C
Reduced adjustable temperature 25-55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 4,1 - 40,0 kW
Nominal heat load 4,2 - 41,0 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 19,0 dm³/min
Energy efficiency class of water heating A
Load profile XL
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 29 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,09 kW
Electricity consumption at partial load elmax 0,06 kW
Type and supply voltage ~230±10%/50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 785 x 400 x 334 mm
Weight 39,5 kg
Domestic water connection G1/2 inch
Exchanger material stainless steel

The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.

Cennik PDF
Cennik Excel
Katalog do systemów kaskadowych
Zamknij okno