Files to download

ECOCONDENS GOLD PLUS

A
A
A
      
 
Wall mounted gas condensing boilers ECOCONDENS GOLD PLUS are characterized by modern, technically advanced design, easy to operate for the installer and the user as well. Components of renowned international companies guarantee the highest level of quality, as well as provide a solution with the highest efficiency.
Technical features of the product – a.o. modulation of the device up to 3 kW, as well as high quality were appreciated by a committee of experts, which resulted in awarding the Gold Medal of 2016 - Poznań International Fair.
ECOCONDENS GOLD PLUS boilers are equipped with remote control systems via smartphone or tablet by an individual customer and remote monitoring of the boiler by a service technician in order to optimize the operation of the devices and increase the operating comfort.
  • new generation stainless steel heat exchanger with aluminium burner door, resulting in less heat loss
  • wide modulation range: from 11 to 100%
  • high efficiency circulation pump
  • stepless speed regulation fan (controlled electronically)
  • cylinder burner made of stainless steel – low level of NOx emission (6th class)
  • complete protection system
  • optimization of boiler operation is possible due to application of:
    • outdoor temperature sensor
    • temperature regulator: ON/OFF, Open-Therm or 0-10V,
    • ROUND system for remote boiler control via smartphone,
    • EVOHOME system for remote control of up to 11 heating zones
    • ready-to-use multi-zone modules for controlling up to 3 SIM heating systems
  • boilers can also cooperate with:
    • heat pumps air/water
    • solar panels
  • possibility of remote monitoring of the boiler by service technician (LIN system)
Parameters Value
Thermal power (at temp. 80/60°C) 3,0 - 19,1 kW
Thermal power (at temp. 50/30°C) 3,4 - 21,0 kW
Heat load 3,1 - 19,5 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
19,1 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
6,3 kW
Efficiency η4 88,1 %
Efficiency η1 98,7 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,0 - 19,1 kW
Nominal heat load 3,1 - 19,5 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,7 dm³/min
Maximum water flow (flow limiter) 10 dm³/min
Domestic water flow at Δt=30K 9 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 46 dB
Emission of nitrogen dioxide 40 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,003 kW
Electricity consumption at full load elmax 0,07 kW
Electricity consumption at partial load elmax 0,05 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G 3/4 inch
Dimensions 750 x 400 x 349 mm
Weight 34,0 kg
Domestic water connection G 1/2 inch
Exchanger material stainless steel
Parameters Value
Thermal power (at temp. 80/60°C) 2,8 - 24,5 kW
Thermal power (at temp. 50/30°C) 3,0 - 27,0 kW
Heat load 2,8 - 25,1 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
97,6 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
107,8 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
24,5 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
8,1 kW
Efficiency η4 88,1 %
Efficiency η1 98,8 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 2,8 - 26,6 kW
Nominal heat load 2,8 - 27,3 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 97,6 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,7 dm³/min
Domestic water flow at Δt=30K 13 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 43 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,07 kW
Electricity consumption at partial load elmax 0,05 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G 3/4 inch
Dimensions 750 x 400 x 349 mm
Weight 33,0 kg
Domestic water connection G 1/2 inch
Exchanger material stainless steel
Parameters Value
Thermal power (at temp. 80/60°C) 4,1 - 31,4 kW
Thermal power (at temp. 50/30°C) 4,5 - 34,6 kW
Heat load 4,2 - 32,0 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
31,4 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
10,4 kW
Efficiency η4 88,3 %
Efficiency η1 99,1 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 4,1 - 35,3 kW
Nominal heat load 4,2 - 36,0 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,7 dm³/min
Domestic water flow at Δt=30K 19,0 dm³/min
Energy efficiency class of water heating A
Load profile XL
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 45 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,09 kW
Electricity consumption at partial load elmax 0,06 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G 3/4 inch
Dimensions 750 x 400 x 349 mm
Weight 36,0 kg
Domestic water connection G 1/2 inch
Exchanger material stainless steel

The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.