Files to download

GOLD PLUS II

A
A
A
Condensing boilers from the GOLD PLUS II series are innovative, modern devices used in radiator and floor heating systems and for the preparation of domestic hot water. The devices are ideal for installation in both new buildings and in newly modernized installations. The elegant and modern appearance makes the device fit perfectly into any interior. Thanks to the use of the latest generation of components, GOLD PLUS II condensing boilers are extremely friendly to the natural environment. It is possible to manage heating via the Internet using the Basic Package for the Termet Comfort System.
  • energy class: A
  • control via the Internet - ability to manage the temperature in the room using a smartphone or tablet using the Termet Comfort System package
  • use of the latest generation of stainless steel heat exchanger with a single coil coil
  • extremely wide power modulation range: from 17% to 100%
  • highly efficient circulation pump
  • fan with smooth speed control (electronically controlled)
  • low NOx stainless steel cylindrical burner (class 6)
  • hydraulic group in the form of a hydroblock mounted on quick connectors
  • complete security system
  • Open-Therm communication system using the CR11011 controller
  • possibility of working with multi-zone modules for heating systems
  • possibility of cooperation with air/water heat pumps
Parameters Value
Thermal power (at temp. 80/60°C) 3,3 - 19,1 kW
Thermal power (at temp. 50/30°C) 3,7 - 21,0 kW
Heat load 3,4 - 19,5 kW
Seasonal space heating energy efficiency ηs 96,1 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
19,1 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
6,3 kW
Efficiency η4 90,4 %
Efficiency η1 100,0 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,6 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,3 - 19,1 kW
Nominal heat load 3,4 - 19,5 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 9 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 33 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,066 kW
Electricity consumption at partial load elmax 0,054 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 793 x 400 x 310 mm
Weight 36,2 kg
Domestic water connection G1/2 inch
Exchanger material INOX steel
Parameters Value
Thermal power (at temp. 80/60°C) 3,3 - 19,1 kW
Thermal power (at temp. 50/30°C) 3,7 - 21,0 kW
Heat load 3,4 - 19,5 kW
Seasonal space heating energy efficiency ηs 96,1 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
19,1 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
6,3 kW
Efficiency η4 90,4 %
Efficiency η1 100,0 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,6 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,3 - 24,5 kW
Nominal heat load 3,4 - 25,0 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 12 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 51 dB
Emission of nitrogen dioxide 33 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,066 kW
Electricity consumption at partial load elmax 0,054 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 793 x 400 x 310 mm
Weight 36,3 kg
Domestic water connection G1/2 inch
Exchanger material INOX steel
Parameters Value
Thermal power (at temp. 80/60°C) 3,3 - 24,5 kW
Thermal power (at temp. 50/30°C) 3,7 - 27,0 kW
Heat load 3,4 - 25,0 kW
Seasonal space heating energy efficiency ηs 95,5 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
24,5 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
8,1 kW
Efficiency η4 90,4 %
Efficiency η1 100,1 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,6 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,3 - 31,4 kW
Nominal heat load 3,4 - 32,0 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 15 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 53 dB
Emission of nitrogen dioxide 35 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,096 kW
Electricity consumption at partial load elmax 0,064 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 793 x 400 x 310 mm
Weight 36,5 kg
Domestic water connection G1/2 inch
Exchanger material INOX steel
Parameters Value
Thermal power (at temp. 80/60°C) 3,6 - 35,3 kW
Thermal power (at temp. 50/30°C) 4,0 - 38,9 kW
Heat load 3,7 - 36,0 kW
Seasonal space heating energy efficiency ηs 93,2 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
35,2 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
11,6 kW
Efficiency η4 89,5 %
Efficiency η1 97,6 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,6 - 35,3 kW
Nominal heat load 3,7 - 36,0 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98,0 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 18 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 51 dB
Emission of nitrogen dioxide 43 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,119 kW
Electricity consumption at partial load elmax 0,061 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 793 x 400 x 342 mm
Weight 39,0 kg
Domestic water connection G1/2 inch
Exchanger material INOX steel

The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.

Cennik PDF
Cennik Excel
Katalog do systemów kaskadowych
Zamknij okno
Informacje o plikach cookies