ECOCONDENS NEX

A
A
A
ECOCONDENS NEX gas condensing boilers are innovative devices of the highest technical level in the category of gas wall-mounted boilers intended for heating and preparing domestic hot water. The high efficiency of the devices as well as the wide range of modulation make these devices very economical and environmentally friendly. Additionally, a guarantee of high comfort of use is the LIN interface, which allows you to connect the Termet Comfort System to remote control via the Internet. The distinguishing feature of the ECOCONDENS NEX series boilers is their extremely smooth and quiet operation.
  • energy class: A
  • modern stainless steel heat exchanger characterized by high resistance to corrosion and scaling
  • the latest generation CERAMAT burner made of ceramic fiber, distinguished by an extremely wide range of modulation, allowing for optimization of the combustion process and gas savings
  • additional boiler soundproofing system based on modern sound-absorbing materials
  • very quiet operation of the boiler - only 37 dB (applies to 24, 28 kW boilers)
  • highly efficient circulation pump
  • electronically controlled modulated fan
  • highest NOx class (class 6)
  • complete security system
  • possibility of working with multi-zone modules for heating systems
  • possibility of cooperation with air/water heat pumps
  • cooperation with domestic hot water tanks through the built-in three-way valve

 

Parameters Value
Thermal power (at temp. 80/60°C) 3,1 - 24,0 kW
Thermal power (at temp. 50/30°C) 3,5 - 26,5 kW
Heat load 3,2 - 24,5 kW
Seasonal space heating energy efficiency ηs 95,5 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
24,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
7,2 kW
Efficiency η4 88,5 %
Efficiency η1 97,5 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,6 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,1 - 29,9 kW
Nominal heat load 3,2 - 30,5 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 14 dm³/min
Energy efficiency of water heating ηwh 82 %
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 37,4 dB
Emission of nitrogen dioxide 46,9 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 8 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,09 kW
Electricity consumption at partial load elmax 0,07 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G 3/4 inch
Dimensions 767 x 450 x 350 mm
Weight 55 kg
Domestic water connection G 1/2 inch
Exchanger material steel INOX
Parameters Value
Thermal power (at temp. 80/60°C) 3,5 - 28,2 kW
Thermal power (at temp. 50/30°C) 3,9 - 31,1 kW
Heat load 3,6 - 28,8 kW
Seasonal space heating energy efficiency ηs 94,2 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
28,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
8,4 kW
Efficiency η4 88,3 %
Efficiency η1 97,4 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40 - 80 °C
Reduced adjustable temperature 25 - 55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,5 - 35,2 kW
Nominal heat load 3,6 - 35,5 kW
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C 98 %
Water pressure 0,1 - 6,0 bar
Minimal water flow 2,0 dm³/min
Domestic water flow at Δt=30K 17 dm³/min
Energy efficiency of water heating ηwh 84 %
Energy efficiency class of water heating A
Load profile XL
Range of water temperature regulation 30 - 60 °C
Sound power level LWA 47,8 dB
Emission of nitrogen dioxide 39,6 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 8 dm³
Standby mode power consumption PSB 0,002 kW
Electricity consumption at full load elmax 0,10 kW
Electricity consumption at partial load elmax 0,07 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G 3/4 inch
Dimensions 767 x 450 x 350 mm
Weight 55 kg
Domestic water connection G 1/2 inch
Exchanger material steel INOX

The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.